Модуль ICP DAS WISE-7902
Цена: 28860 руб
Артикул: | WISE-7902 | Доставка: | от 800 р. по Москве |
Постоянным клиентам и при заказе от 50 000 рублей предоставляются скидки |
Если вы нашли товар по более низкой цене – мы готовы поставить его Вам по меньшей стоимости
|
FRnet Remote I/O PoE Module Спецификация | System | | Процессор | 16-bit CPU | SRAM | 512 KB | Flash Memory | 512 KB | EEPROM | 16 KB | Сторожевой таймер | Да (0.8 секунд) | NVRAM | 31 Bytes | ОС | MiniOS7 | Часы реального времени | RTC Provide seconds, minutes, hours, date of week/month month and year, valid from 1980 to 2079 | 64-бит ключ | Да | Интерфейсы | | PoE Ethernet Port | RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) | COM 1 | No (Unsupported by WISE firmware) | COM 2 | No (Unsupported by WISE firmware) | FRnet | Max. 1 M | LED Indicators | | System LED | Yes (Red) | LED Display | - | Special Indicator | PoE LED (Green) | Power Requirements | | Reserve Polarity Protection | Да | Powered from PoE | Yes, IEEE 802.3af, Class1 | Consumption | 1.5 W | Frame Ground | Yes (for ESD Protection) | Input Range | +12 ~ +48 VDC | Mechanical | | Dimensions (W x H x D) | 72 mm x 123 mm x 35 mm | Installation | DIN-Rail or Wall mounting | Environment | | Operating Temperature | -25 °C ~ +75 °C | Storage Temperature | -40 ~ +80 °C | Humidity | 5 ~ 90% RH, non-condensing | Functions | | Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. | 36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions | 48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. | 12 Timers | Delay / Timing functions | 12 Schedules | Setup prescheduled routine tasks. | 12 Emails | Send Email messages to pre-set Email receivers. | 12 CGI Commands | Send pre-set CGI commands. | 12 Recipes | Set up THEN/ELSE action groups. | 8 P2P remote modules | Set up the connection information for the remote WISE modules. | Modbus/TCP Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. | IF Conditions | | DI Channel | ON, OFF, ON to OFF, OFF to ON, Change | Internal Register | =, and lt , and gt , and gt =, and lt = (value) | DI Counter | =, and gt , and lt , and gt =, and lt =(value), Change | DO Counter | =, and gt , and lt , and gt =, and lt =(value), Change | Timer | Timeout, Not Timeout | Schedule | In Range, Out of Range | P2P | DI, AI, DI counter, DO counter, IR | Rule Status | Enable, Disable | THEN / ELSE Actions | | DO Channel | ON, OFF, Pulse Output | Internal Register | Change the value | DI Counter | Reset | DO Counter | Reset | Timer | Start, Stop | Schedule | Start, Stop | Email | Send | CGI Commands | Send | Recipe | Execute | P2P | DO(On/Off), AO, IR | Rule Status | Enable, Disable |
|