Модуль ICP DAS WISE-5800

Цена: 33950 руб

Если вы нашли товар по более низкой цене – мы готовы поставить его Вам по меньшей стоимости
Артикул: WISE-5800
Доставка: от 800 р. по Москве
Постоянным клиентам и при заказе от 50 000 рублей предоставляются скидки
User-defined I/O and Data Logger Module


Спецификация
System
Процессор 16-bit CPU
SRAM 768 KB
Flash Memory 512 KB
EEPROM 16 KB
Сторожевой таймер Да (0.8 секунд)
NVRAM 31 Bytes
Часы реального времени RTC Provide seconds, minutes, hours, date of week/month month and year
microSD Yes, can support 1 or 2 GB microSD
Интерфейсы
PoE Ethernet Port RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
COM 1 RS-232 (Reserved, Unsupported by WISE firmware)
COM 2 RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max.
LED Indicators
System LED Yes (Red)
LED Display -
Ethernet Link LED Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)
Hardware Expansion
I/O Expansion Bus Да
Power Requirements
Reserve Polarity Protection Да
Consumption 2.0 W
Frame Ground Yes (for ESD Protection)
Input Range +12 ~ +48 VDC
Redundant Power Input Да
Mechanical
Dimensions (W x H x D) 91 mm x 123 mm x 52 mm
Installation DIN-Rail
Environment
Operating Temperature -25 °C ~ +75 °C
Storage Temperature -30 °C ~ +80 °C
Humidity 10 ~ 90% RH, non-condensing
Functions
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions
12 Schedules Setup prescheduled routine tasks.
12 Emails Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
Data Logger Set up the Data Logger configuration, include the data record format, and data file sending operation.
IF Conditions
DI Channel ON, OFF, ON to OFF, OFF to ON, Change
AI Channel =, and lt , and gt , and gt =, and lt = (value)
Internal Register =, and lt , and gt , and gt =, and lt = (value)
DI Counter =, and gt , and lt , and gt =, and lt =(value), Change
Timer Timeout, Not Timeout
Schedule In Range, Out of Range
Rule Status Enable, Disable
THEN / ELSE Actions
DO Channel ON, OFF, Pulse Output
AO Channel Change the value
Internal Register Change the value
DI Counter Reset
Timer Start, Stop
Schedule Start, Stop
Email Send
CGI Commands Send
Recipe Execute
Rule Status Enable, Disable
Data Logger Start, Stop, One-Time Log